How do you increase the insulation resistance of a motor?

Cleaning and drying the winding will usually improve the IR. If the winding temperature is at or below the dew point, moisture may accumulate on the surface, causing low IR values. When the winding is otherwise in good condition, drying will resolve this issue.

How can insulation resistance be improved?

After the etching away of copper to selectively expose surface areas of insulating material in a printed circuit process based upon copper foil-clad insulating substrate material, the exposed surface areas of insulating material are contacted with an aqueous alkaline permanganate solution to remove from the areas …

What should be the insulation resistance of motor?

It is recommended that the insulation resistance of the motor should at least be 1 MΩ1, and for the voltage to ground of 200 V, I0r should be 200 μA or below.

How do you calculate insulation resistance?

How is insulation resistance calculated and tested? We should all be familiar with Ohm’s law. If we apply a voltage across a resistor and then measured the consequential current flow, we can then use the formula R=U/I, (where U=Voltage, I=Current and R=Resistance) to calculate the resistance of the insulation.

What is a good Meg reading on a motor?

Our minimum meg readings are 1.5 megs for 480 volt motors at 1000 volt meg. (That would be 1.5 million ohms to ground resistance.) 1.5 to 20 is fair. 20 to 50 is good.

THIS IS IMPORTANT:  Are cars with turbo engines more expensive to insure?

What is a bad Megger reading?

What is a bad reading on a Megger test? If the megger reads a resistance under 1 (1,000 ohms) on your meter after the initial 60-second interval, the cable has failed and the cable should be removed. If the megger reads a resistance between 1-1.25 on your meter, then the cable passes.

What are the two main factors that affect insulation resistance?

Factors that affect insulation resistance measurements include such things as temperature, humidity, previous conditioning, test voltage, charging current and duration of the test voltage (electrification time).

What is the minimum acceptable value of insulation resistance?

Insulation resistance should be approximately one megohm for each 1,000 volts of operating voltage, with a minimum value of one megohm. For example, a motor rated at 2,400 volts should have a minimum insulation resistance of 2.4 megohms.

Does insulation affect resistance?

Resistance and Thickness

There is also a strong relationship between the resistance of a cable and the thickness of the insulator. Increase in thickness means increase in resistance, and the opposite is also true. If thickness is reduced, the resistance of the insulator also reduces.